KFCi Technology

  • Leading edge communications systems based upon radio transmission technology.
  • Facilitates rapid transmission of signals, saving critical seconds during emergency situations in the most diverse conditions.

What’s the advantage to this technology?

  • Cost effective when compared to hard-wired systems.
  • Faster transmission saving critical seconds in emergency situations.
  • User friendly, specifically designed computer-aided dispatch software.

KFCi's Product Line and Customer Base

  • KFCi's customer base includes commercial, industrial, institutional and military customers throughout the world.
  • Our systems are currently in service in Alaska, Japan, Korea, Guam, Hawaii and the continental United States.  
  • KFCi products can be located in diverse locations such as Antarctica, Middle East and Persian Gulf area.  
  • We can transmit to all major fire alarm control panels.

 

 

 

KF200 Series Smoke Detectors Low Profile

200 Series Smoke Detector Low Profile 

 

The KF200 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary address switches. This provides exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level.

>> SPEC SHEET

 

   KFALC-198 Analog Loop Controller Module

 King-Fisher ALC-198 Analog Loop Controller Module

The KFALC-198S Single Analog Loop Controller Module provides an additional analog loop to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules. The KFALC-198S occupies one module slot in the FX-2000 main or expander chassis.

>> SPEC SHEET

 

KFALC-396S Dual Intelligent Analog Loop Controller Module

 

The KFALC-396S Dual Analog Loop Controller Module provides two additional analog loops to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules per loop.

>> SPEC SHEET 

 

KFIPS-2424 Programmable Input Switch Module

The KFIPS-2424 Programmable Input Switch Module, which provides 24 programmable switches complete with bi-colored LEDs and slide-in labels, can be configured for auxiliary functions such as zone by-pass or added common control functions. In a zone bypass configuration, a group of addressable devices or hardwired circuits can be assigned to a programmable switch and when the switch is operated, those devices or zones are by-passed. The switches operate in an alternating toggle operation for on and off. There are two LEDs for each switch; one for selection, the other is bi-colored to indicate point status when the switch is returned to normal (unbypassed) position. The bi-colored LED will flash red to indicate an alarm or it will flash amber to indicate that a trouble alarm will be processed when the switch is returned to normal (unbypassed) position. The KFIPS-2424 can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display if unique programmable input switches are required for a specific location. The KFIPS-2424 takes up two frames when connected to the main or remote shared display. The KFIPS-2424 occupies one display position in the BB-1000 or BB-5000 enclosures.

>>SPEC SHEET


KFFR2 Fast Rail 2 Module Holder

Fast Rail 2 Module Holder 

The KFFR2 fast rail is designed to hold up to two System Sensor style addressable modules with a quick snap in assembly. Ideally suited for addressable module installations. Each address module is installed independently with the field wiring connections and address dials easily accessible. The KFFR2 is supplied with edge protectors to eliminate wire to wire or wire to ground shorts when pulling wire. The KFFR2 is ideally suited for the AC 2 cabinet for a professional installation. Features key access and a lift away removable door to access the addressable modules and field wiring thus allowing you time saving maintenance and troubleshooting of the system.

>>SPEC SHEET

 

KFFDX008 Fan Damper Control Display Module

 

King-Fisher FDX008 Fan Damper Control Display Module Rev

The KFFDX-008 Fan Damper Module provides individually programmed circuits which can be used for fan or damper control. Each circuit has a slide-in label, a three position selector switch, green “run or open” LED and an amber “off or closed” LED. The three-position selector switch has a centre “auto” position, a left “off or close” position and a right “on or open” position. The KFFDX-008 connects t+o the main panel or the RAX-LCD when mounted remotely. It uses M500CH for control of fans or dampers and two M501A for status. The KFFDX-0008 occupies one display position on the FX-2017-12A Main Chassis.

>> SPEC SHEET

 

KFALC-H16 Hardwired Loop Controller Module

 

ALC-H16 Hardwired Loop Controller Rev.jpg

The KFALC-H16 Hardwire Loop Controller Module allows the FX-2003RT or FX-2000 to support an additional sixteen (16) conventional hardwire adder modules. The hardwire modules consist of the DM-1008 Eight Initiating Circuit Module, SGM-1004 Four Indicating Circuit Module and the RM-1008 Eight Relay Circuit Module. The KFALC-H16 occupies one module slot in the FX-2000 Series main or expander chassis.

>>SPEC SHEET

 

KF700ADU Series Manual Station

KF710ADU

The KF700ADU Series Manual Station provides manual fire reporting. This high quality, die-cast metal Intelligent Fire Alarm Manual Station is available as either single or dual action devices with key reset and a permanently attached addressable module. The addressable manual station has a pair of rotary decimal switches which allows for two digit address setting.

 >>SPEC SHEET

 

KF710ADU Pull Station

KF710ADU

The KF710ADU Pull Station provides Manual fire reporting. This high quality, die-cast metal Intelligent Fire Alarm Pull Station is available in a dual action configurations with a permanently attached addressable module. The KF710ADU Pull Station is available with a CAT-211 key and mounts on a standard single gang backbox or model BB-700 interior surface metal backbox. The KF710ADU addressable pull station has a pair of rotary decimal switches which allows for two digit address setting. Pulling the handle initiates the operation of the addressable module.

>>SPEC SHEET

 

Intelligent Non-Relay Photoelectric Duct Smoke Detector

 

 King-Fisher KFDNR Duct Smoke Detector Rev

The Innovair Flex KFDNR intelligent non-relay photoelectric duct smoke detector and KFDNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. KFDNRW duct smoke detector, with its NEMA 4 rating, is listed as a watertight enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). An improved cover design isolates the sensor head from the low flow feature for simple maintenance. A cover tamper feature was added to indicate a trouble signal for a removed or improperly installed sensor cover. The Innovair Flex housing provides a ¾ inch conduit knockout and ample space to facilitate easy wiring and mounting of relay module. The Innovair Flex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new Innovair Flex product line is compatible with all previous Innovair models, including remote test accessories.

>>SPEC SHEET


Intelligent ADressable KFDMM

 

 M500DM

The Intelligent Addressable Dual Monitor Module (KFDMM) provides two independent 2-wire initiating device circuits at two separate, consecutive addresses. It is capable of monitoring two separate Class B (Style B) circuits simultaneously, making it ideal for water flow and tamper switch monitoring. The KFDMM has a single activated red LED that is common to either circuit.

>>SPEC SHEET

 

KFsMM

 

 M500M

The Intelligent Addressable Monitor Module KFSMM provides an address for a group of UL/ULC Listed normally open (N.O.) initiating devices, such as heat detectors, beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The KFSMM has an activated red LED.

>>SPEC SHEET

 

Intelligent Relay Control Module KFRM

M500R

The Intelligent Addressable Relay Module connects to the same loop as the initiating devices and provides two isolated sets of Form-C contacts. The module allows the FX-2000 Series fire alarm control panel to switch these contacts on command. The KFRM has an activated red LED which follows the state of the relay contacts.

>>SPEC SHEET

 

Intelligent Isolator Module KFFIM

M500X

The KFFIM Fault Isolator Modules enable part of the communications loop to continue operating when a short circuit occurs on it. An LED indicator blinks in the normal condition and turns on during a short circuit condition. The module will automatically restore the entire communications loop to the normal condition when the short circuit is removed.

>>SPEC SHEET

 

Intelligent Monitor Module KFMMM

M501M

The Intelligent Addressable Mini Monitor Module in the FX2003 Series Fire Alarm Panel provides an address for a group of UL Listed Normally Open (N.O.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class B (Style B) initiating circuit.

>>SPEC SHEET

 

 Itelligent Zone Interface Module KFZIM

M502M

 

 

The KFZIM provides the same features as the KFSMM for the FX2003 Series Fire Alarm Panel but also allows for the use of multiple, conventional 2-wire smoke detectors in the circuit. This module requires a resettable signal power source. The KFZIM internally supervises the separate power source. The red LED indicates when the module is activated. All two-wire detectors that are monitored must be UL compatible with the KFZIM module.

>>SPEC SHEET

KFMGD-32 Master Graphic Driver Board

 

The KFMGD-32 Master Graphic Driver Module with the FX2003 Series Fire Alarm Panel provides common control inputs for the common control switches such as System Reset, Signal Silence, Auxiliary Disconnect, Fire Drill, Lamp Test, Acknowledge and General Alarm. Any or all of these switch inputs can be used. There are supervised outputs for all of the support LEDs and the common control switches. The KFMGD-32 can also drive up to 32 supervised outputs. These output points are capable of driving LEDs or incandescent lamps.

>>SPEC SHEET

 

KFPR300 Polarity Reversal Module

 

pr300 

The KFPR-300 with the FX2003 Series Fire Alarm Panel provides outputs for city box and polarity reversal applications. The KFPR-300 provides off premises signal transmission for systems that must comply with NFPA requirements for Auxiliary Protective Systems.

>>SPEC SHEET

 

KFRAX-048

RAX 048

The KFRAX-048 Programmable Zone LED Annunciator Module provides 48 programmable bi-colored LEDs. The KFRAX-048 is used if additional LED zone annunciation is required. The addressable points can be grouped together to light one LED, or they can be part of many groups and therefore may turn on many LEDs. The circuits can be selected as either Alarm to illuminate the red LED or for Supervisory to illuminate the amber LED. Any zone trouble condition will be displayed on the Shared Display. The KFRAX-048 can be connected to the main panel or it can be connected to the KFRAX-LCD Remote Shared Display if a programmable remote LED annunciator is required. When configured in this manner, it requires two frames when connected to either the main or remote shared display.

The KFRAX-048 is used in conjunction with the KFRAX-LCD when a different type of annunciation configuration or a different location is required. The KFRAX-048 occupies one display position in the BB-1000 or BB-5000 enclosures.

>>SPEC SHEET

 

KFRAX-LCD

 

RAX LCD

The KFRAX-LCD Remote Shared Display is a remoteannunciator that provides the same functions as the main display on the FX2003 panel, less 16 zone LEDs.

It is equipped with a large 4 line x 20 character back-lit alphanumeric LCD display which uses a simple menu system complete with a directional keypad and switches for Enter, Menu, Cancel and Info. It also has 4 Alarm switches and LEDs as well as common control switches and LEDs for Signal Silence, Fire Drill, System Reset, Lamp Test, General Alarm and Acknowledge. The KFRAX-LCD can be programmed to show different points than the main panel. In addition to being a remote annunciator, the KFRAX-LCD can also be used as a driver module for standard LED annunciation or reduced zone annunciation (different from the main panel annunciation), graphic drivers programmed different from the main annunciators, programmable switch modules with their unique configuration and fan damper control also with their unique configuration.

Each time a different type of annunciation configuration is required or a different location is required an additional KFRAX-LCD will be needed. The KFRAX-LCD allows for the control switches to be disabled on a per function basis (via laptop configurator) for areas that do not require certain Common Control functions to be remotely located from the Fire Alarm Control Panel. The KFRAX-LCD occupies one display position in the BB-1000 or BB-5000 enclosures.

>>SPEC SHEET

 

KFRM-1008A Eight Relay Circuit Module

RM-1008A Eight Relay Circuit Module

 

The RM-1008A provides the FX-2003 with 8 individual configurable relays per module. Each relay provides one Form C contact rated at 28 VDC @1 Amp (resistive load). The KFRM-1008A occupies one module slot in the FX-2003 main or expander chassis.

 >>SPEC SHEET

 

KFSGM-1004A 4 Signal Adder Module

 

SGM1004A 4 Signal Adder Module Rev

The KFSGM-1004A is a 4 Indicating Zone Module used with the FX2003 Series Fire Alarm Panel providing 4 Class A/B (Style Z/Y) Indicating Circuits configurable as Silenceable or Non-Silenceable. Each Indicating Circuit is rated at 1.7 Amps. Each of the indicating circuits have individual LED indicator for status verification.

>>SPEC SHEET