KFCi Technology

  • Leading edge communications systems based upon radio transmission technology.
  • Facilitates rapid transmission of signals, saving critical seconds during emergency situations in the most diverse conditions.

What’s the advantage to this technology?

  • Cost effective when compared to hard-wired systems.
  • Faster transmission saving critical seconds in emergency situations.
  • User friendly, specifically designed computer-aided dispatch software.

KFCi's Product Line and Customer Base

  • KFCi's customer base includes commercial, industrial, institutional and military customers throughout the world.
  • Our systems are currently in service in Alaska, Japan, Korea, Guam, Hawaii and the continental United States.  
  • KFCi products can be located in diverse locations such as Antarctica, Middle East and Persian Gulf area.  
  • We can transmit to all major fire alarm control panels.

 

 

 

FX-2000 Intelligent
Analog Fire Alarm
Control Panel

The FX-2000 Fire Alarm Control Panel is equipped with a large 4 line by 20 character back-lit LCD display with user friendly menu, the FX-2000 supports both analog loop controllers as well as conventional circuit modules. The modular design of the system allows for configurable units such as Programmable Input Switches, Fan Damper Control Modules, Programmable LED annunciators and Graphic Annunciators. In addition the FX-2000 comes equipped with two event history logs and four alarm sequences for simple yet detailed information. Designed for maximum flexibility, the FX-2000 provides easy installation and operation at a
cost-effective price. Along with the large 4 x 20 Back-lit Alphanumeric LCD display, the FX-2000 utilizes a simple Menu system complete with a directional keypad, common control switches and LEDs, Alarm sequence switches and LEDs, two configurable input switches and 16 configurable zone LEDs.

>>SPEC SHEET

KFAPT
Addressable
Transmitter

The KFAPT gives emergency responding personnel detailed prior knowledge before arriving at the scene of an emergency. Advance information of a specific smoke detector, sprinkler waterflow or manual pull station in alarm or trouble. Knowledge of the condition of any combination of initiating alarm devices can save precious minutes or even precious seconds by preplanning the response prior to arriving at the scene. The KFAPT Addressable Transmitter provides the most reliable and efficient means of transmitting radio coded alarm and trouble signals to an Emergency Service Dispatch Center having a KFRA-C radio fire alarm receiver(s) up to 25 miles away. The KFAPT can transmit instantaneously up to 1008 addressable devices. Individual coded alarm and trouble signals include smoke detectors, heat detectors, manual pull stations, sprinkler flow, tamper and much more. In fact all alarm and trouble signals received by the addressable fire alarm panel are duplicated by the KFAPT and transmitted.

>> SPEC SHEET

 

Fire Alarm Control Panel Modules

RAX-LCD
Remote Shared Display

RAX-LCD Remote Shared Display: The RAX-LCD Remote Shared Display is a remote annunciator that provides the same functions as the main display on the FX2003 panel, less 16 zone LEDs. It is equipped with a large 4 line x 20 character back-lit alphanumeric LCD display which uses a simple menu system complete with a directional keypad and switches for Enter, Menu, Cancel and Info. It also has 4 Alarm switches and LEDs as well as common control switches and LEDs for Signal Silence, Fire Drill, System Reset, Lamp Test, General Alarm and Acknowledge. The RAX-LCD can be programmed to show different points than the main panel. In addition to being a remote annunciator, the RAX-LCD can also be used as a driver module for standard LED annunciation or reduced zone annunciation (different from the main panel annunciation), graphic drivers programmed different from the main annunciators, programmable switch modules
with their unique configuration and fan damper control also with their unique configuration. Each time a different type of annunciation configuration is required or a different location is required an additional RAX-LCD will be needed. The RAX-LCD allows for the control switches to be disabled on a per function basis (via laptop configurator) for areas that do not require certain Common Control functions to be remotely located from the Fire Alarm Control Panel. The RAXLCD occupies one display position in the BB-1000 or BB-5000 enclosures.

>> SPEC SHEET

IPS-2424
Programmable Input
Switch Module

The IPS-2424 Programmable Input Switch Module, which provides 24 programmable switches complete with bi-colored LEDs and slide-in labels, can be configured for auxiliary functions such as zone by-pass or added common control functions.
In a zone bypass configuration, a group of addressable devices or hardwired circuits can be assigned to a programmable switch and when the switch is operated, those devices or zones are by-passed. The switches operate in an alternating toggle operation for on and off. There are two LEDs for each switch; one for selection, the other is bi-colored to indicate point status when the switch is returned to normal (unbypassed) position. The bi-colored LED will flash red to indicate an alarm or
it will flash amber to indicate that a trouble alarm will be processed when the switch is returned to normal (unbypassed) position. The IPS-2424 can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display if unique programmable input switches are required for a specific location. The IPS-2424 takes up two frames when connected to the main or remote shared display.
The IPS-2424 occupies one display position in the BB-1000 or BB-5000 enclosures.

>> SPEC SHEET

FDX-008
Fan Damper Control
Display Module

The FDX-008 Fan Damper Module provides individually programmed circuits which can be used for fan or damper control. Each circuit has a slide-in label, a three position selector switch, green "run or open" LED and an amber "off or closed" LED. The three-position selector switch has a centre "auto" position, a left "off or close" position and a right "on or open" position. The FDX-008 connects to the main panel or the RAX-LCD when mounted remotely. It uses M500CH for control of fans or dampers and two M501A for status. The FDX-0008 occupies one display position on the FX-2017-12A Main Chassis.

>> SPEC SHEET

RAX-048
Programmable Zone LED
Annunciator Module

The RAX-048 Programmable Zone LED Annunciator Module provides 48 programmable bi-colored LEDs. The RAX-048 is used if additional LED zone annunciation is required. The addressable points can be grouped together to light one LED, or they can be part of many groups and therefore may turn on many LEDs. The circuits can be selected as either Alarm to illuminate the red LED or for
Supervisory to illuminate the amber LED. Any zone trouble condition will be displayed on the Shared Display. The RAX-048 can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display if a programmable remote LED annunciator is required. When configured in this manner, it requires two frames when connected to either the main or remote shared display. The RAX-048 is used in conjunction with the RAX-LCD when a different type of annunciation
configuration or a different location is required. The RAX-048 occupies one display position in the BB-1000 or BB-5000 enclosures.

>> SPEC SHEET

FR2
Fast Rail 2 Module Holder

The FR2 fast rail is designed to hold up to two System Sensor style addressable modules with a quick snap in assembly. Ideally suited for addressable module installations. Each address module is installed independently with the field wiring connections and address dials easily accessible. The FR2 is supplied with edge protectors to eliminate wire to wire or wire to ground shorts when pulling wire. The FR2 is ideally suited for the ACE 2 cabinet for a professional installation. Features key access and a lift away removable door to access the address modules and field wiring thus allowing you time saving maintenance and trouble shooting of the
system.

>> SPEC SHEET

M500M
Intelligent Addressable
Monitor Module

 

The Intelligent Addressable Monitor Module (M500M) provides an address for a group of UL/ULC Listed normally open (N.O.) initiating devices, such as heat detectors, beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The M500M has an activated red LED.

>> SPEC SHEET

M-500 Series
Intelligent Addressable
Modules

 

The M-500 Series intelligent module products are designed to meet a wide range of applications. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, waterflow switches, conventional smoke detectors and more. The modules are addressed with easy-to-use rotary code switches and mount in a standard 4" x 4".

>> SPEC SHEET

Intelligent Addressable Monitor
Module (M500M)

The Intelligent Addressable Monitor Module provides an address for a group of UL/ULC Listed normally open (N.O.) initiating devices, such as heat detectors, beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The
M500M has an activated red LED.

>> SPEC SHEET

Intelligent Addressable Dual
Monitor Module (M500DM)

The Intelligent Addressable Dual Monitor Module provides two independent 2-wire initiating device circuits at two separate, consecutive addresses. It is capable of monitoring two separate Class B (Style B) circuits simultaneously, making it ideal for water flow and tamper switch monitoring. The 500DM has a single activated red LED that is common to either circuit.

>> SPEC SHEET

Intelligent Addressable Interface
Module (M502M)

The M502M provides the same features as the M500M but also allows for the use of multiple, conventional 2- wire smoke detectors in the circuit. This module requires
a resettable signal power source. The M502M internally supervises the separate power source. The red LED indicates when the module is activated. All two-wire detectors that are monitored must be UL/ULC compatible with the M502M module.

>> SPEC SHEET

Intelligent Addressable Mini-
Monitor Module (M501M)

The Intelligent Addressable Mini Monitor Module provides an address for a group of UL/ULC Listed Normally Open (N.O.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class B (Style B) initiating circuit.

>> SPEC SHEET

Intelligent Addressable Supervised
Control Module (M500S)

The M500S Control module provides supervised monitoring of wiring to signal devices that require an external power supply to operate, such as horns, strobes, bells or speaker isolators. Conventional signals will require a 24 VDC power source and speakers will require an audio input. The M500S does not supervise the power source. A UL/ULC EOL relay such as the PAM-3 is required. The red LED will illuminate when the module is activated. The module is capable of Class A (Style Z) or Class B (Style Y) supervision.

>> SPEC SHEET

Intelligent Addressable Relay
Module (M500R)

The Intelligent Addressable Relay Module connects to the same loop as the initiating devices and provides two isolated sets of Form-C contacts. The module allows the FX-2000 fire alarm control panel to switch these contacts on command. The M500R has an activated red LED which follows the state of the relay contacts.

>> SPEC SHEET

Fault Isolator Module (M500X)

The M500X Fault Isolator Module is used to protect the system against wire-to-wire short circuits on the analog loop. The modules should be spaced between groups of sensors or modules in a loop to protect the rest of the loop. In the event of a short circuit between any two fault isolator modules, both modules immediately switch to an open circuit condition and isolate any group of sensors between them. The remaining units on the circuit will continue to operate in a normal fashion (must be wired in Class ‘A' or Style 6). A maximum load of 25 devices can be connected to an isolator to insure that the isolator powers up correctly.

>> SPEC SHEET

About Us | Contact Us

King-Fisher Company, inc.